Virtual Valve Museum

Virtual Valve Museum

HomeFull List

This is an archive website. It will not receive any updates, additions or corrections.

CV2240 RF pentode

Size
This valve measures 51x17mm overall and has a B7G base

Filament voltage (parallel)1.25V
Filament voltage (series)2.5V
Filament current (parallel)330mA
Filament current (series)165mA
Max anode voltage (Ia=0)150V
Max screen voltage (Ig2=0)135V
Max anode current25mA
Max screen current1.5mA
Max anode dissipation3W
Max screen dissipation1.1W
Mutual conductance (Va=200, Vg2=150, Vg1=-25)1.85mA/V
Max operating frequency100MHz
Capacitances (with metal shield)
Cag1 max0.16pF
Cin nom4.5pF
Cout nom7.5pF


PinFunction
1Screen grid
2Filament centre tap, suppressor grid and internal shield
3Control grid
4Filament -ve
5Filament +ve
6Filament centre tap, suppressor grid and internal shield
7Anode

Note that for parallel filament connection pins 2 and 6 are negative and pins 4 and 5 are positive

CV2240