CV466 HF pentode
 |
This valve measures 37x9cm
overall, plus leads, and has 8 leads. |
Heater voltage |
6.3V |
Heater current |
200mA |
Max anode voltage (Ia=0) |
350V |
Max screen voltage (Ig2=0) |
350V |
Max anode dissipation |
1.5W |
Max screen dissipation |
1.0W |
Max 'total' dissipation |
2.0W |
Max operating anode voltage |
190V |
Max operating screen voltage |
190V |
Mutual conductance * |
5.5mA/V |
Anode impedance * |
250k ohms |
Anode current * |
7.5mA |
Screen current * |
2.5mA |
Max cathode current |
14mA |
Inner amplification factor |
28 |
Capacitances
(shielded) |
Cin nom |
5.0pF |
Cout nom |
4.5pF |
Ca,g1 max |
0.15pF |
*: At Va=Vg2=100; Vg1=-2.0
Lead |
Function |
1 |
Control grid |
2 |
Suppressor grid |
3 |
Heater |
4 |
Anode |
5 |
Screen grid |
6 |
Heater |
7 |
Cathode |
8 |
Anode |
|
 |