CV139 grounded-grid triode
 |
This valve measures 50x17mm
approx, and has a B7G base |
Heater voltage |
6.3V |
Heater current |
0.3A |
Max anode
voltage |
250V |
Max anode dissipation |
Without can |
2.5W |
Max mean cathode
current |
15mA |
Mutual conductance |
At Va=250V;
Vg=-1.5V; Ia=10mA |
9.0mA/V |
Amplification factor |
100 |
Min grid voltage
to be available
to ensure cut-off to a slope of 100µA/V |
-8V |
Max h-k voltage |
150V |
Max g-k voltage |
100V |
Max operating
frequency |
250MHz |
Capacitances |
Ca-ch |
At 1MHz with
close
fitting metal can
connected to grid |
0.1pF |
Cg-ch |
5.1pF |
Chc |
8.6pF |
Pin |
Function |
1 |
Grid |
2 |
Cathode |
3 |
Heater |
4 |
Heater |
5 |
Cathode |
6 |
Grid |
7 |
Anode |

|
 |